ID |
Product |
Manufacturer |
Model # |
Model 2 |
Status |
|
 | 2551 | Microscope:Camera | Hamamatsu | C4742-95-12NR | | Available |
Description/Details: The ORCA-HR is a high resolution digital camera using a large format interline CCD chip with no mechanical shutter. In addition to a high resolution of 10 million pixels. a wide dynamic range of 12 bit digital output and high sensitivity offers a wide application range down to low light level imaging.
Peltier cooling drastically reduces dark noise and minimizes thermal drift. which makes the camera an ideal choice for demanding scientific and industrial applications.
Features
High resolution of 10 million pixels
Lens coupling : F-mount. ENG (optional)
Low dark noise with peltier cooling
Full remote control from PC via RS-232C
Vertical overflow drain structure
Anti-blooming function
Large format interline CCD chip with no mechanical shutter
Shortest exposure time : 330 µs capture fast events
Binning (2 ×2. 4 ×4) function to improve sensitivity
Imaging device Large format interline CCD (HR-1000)
Wavelength (min.) 320 nm
Wavelength (max.) 980 nm
QE (max.) 50% ... |
|
|
 | 5325 | Microscope:Camera | Nikon | UFX-II | | Available |
Description/Details: Polaroid film camera |
|
|
 | 5324 | Microscope:Camera | Nikon | U-III | | Available |
Description/Details: Multi-Point Sensor System w/ remote
NIKON - U-III Advanced Auto-Photomicrographic Film Camera
The U-III's compact, sleek design and advanced exposure system with Multi-point sensor, make it the system of choice for serious fluorescence applications including FISH. It is ideal for use at research institutes and universities and wherever quick, precise exposure settings are essential.
Details
• Fluorescent Control Panel LCD display with backlight illumination for easy key entry, even in the dark
• Highly-sensitive multipoint sensor to ensure accurate exposure from average light measurement of 35% down to spot measurement. This is essential for determining exposures for microscopic specimens
• Multipoint sensor automatically determines optimum exposure by rapidly scanning the target area
• Features same swing-out beamsplitter system and direct projection lens system as the H-III and P-III, which delivers 100% of the light to the film for the fastest exposure... |
|
|
 | 6082 | Microscope:Camera | IonOptix | MyoCam | w/CFA200 585nm Dichroic & Electron Tube | Available |
Description/Details: High-Speed Contractility Camera
|
|
|
 | 6160 | Microscope:Camera | Roper Scientific | Quantix | | Available |
Description/Details: Quantix® is an F-mount or C-mount, air-cooled imaging system for acquiring digital scientific data. The system provides a fast focus, fast frame rate, and fast readout rate, while still providing the ability to acquire low-light images by integrating over long periods of time
Details:
Roper Scientific Quantix (KAF1401E) 1.4 MegaPixel Air Cooled
Includes PCI Interface card, cable and Power supply
Features:
Scientific-Grade
CCD Single-window Imaging Path
ITO Transparent Gates
Three Detection Modes
Flexible Binning and Readout
12-Bit Digitization
Thermoelectric Cooling
Compact Camera Head
... |
|
|
 | 2593 | Microscope:Camera & Controller | Carl Zeiss | MC 80 DX | | Available |
Description/Details: Camera and controller sold together. The MC 80 DX Microscope Camera is a photomicrographic camera, which fits all Zeiss microscopes having a standard camera port. The MC 80 DX Microscope Camera fits to the standard camera port of Zeiss microscopes via a camera adapter sleeve. There are different adapters, to be used depending on whether the microscope has a camera port for 60 mm or 44 mm image distance. All camera functions of the MC 80 DX are controlled through a control Console with a clearly arranged operating panel providing operator guidance. Its automatic exposure function and easy operation makes
the MC 80 DX ideal for photomicrographic routine.
The MC 80 DX provides the following functions:
Automatic exposure, with exposure metering averaged over the central 30% of the frame.
Automatic reading of the ISO film speed rating from DX-coded 35 mm film cartridges.
Automatic film leader winding and film advance; power rewinding.
Method-specific exposure corrections (+2 ... -3 exp... |
|
|
 | 4597 | Microscope:Camera Controller | Optronics Engineering | DEI-470 | | Available |
Description/Details: Microsope Video Cameras with Built-in Digital Imaging. Digital Edge Sharpening convolution filter operates in real-time to expand the finedetails of soft-focus or low contrast images. The unique filter enhances video prints andcomputer images to more closely resemble the subjects as viewed in the microscope oculars.
Digital Contrast & Brightness Enhancement enable control of video gain and offset to improve dim, low contrast images due to fading and weak fluorochrome emissions.
The Video System Controller contains a built-in 1.5 megabyte 24 bit frame grabber to allow freeze frame imaging. No external microprocessor is required. The controller is preprogrammed to withstand the rigors of a multi-user environment.
... |
|
|
 | 3733 | Microscope:Confocal | Atto Bioscience | Pathway HT | Confocal BioImager | Available |
Description/Details: |
|
|
 | 3558 | Microscope:Controller | Olympus Co | PM-CB20 | Exposure Control Unit | Available |
Description/Details: The control box for the Olympus PM-20 camera has a liquid crystal display that permits user-controlled entry for such items as film size, ISO rating of film, exposure adjust for unusual lighting conditions, reciprocity setting, automatic ISO setting for DX coded film, double exposure capability, exposure lock, bracketing exposure settings, color temperature accessory, lighted frame for fluorescence, and several other variables. The PM-20 has a built-in silicon photodiode system whose meter reads the central 30 percent of the field of view or, using the spot meter lever, the central 1 percent of the field of view. The automatic exposure meter reads the "live" image continuously until the shutter closes. The PM-20 has a setting for fluorescence microscopy whose algorithm automatically reduces the exposure time by 80 percent to prevent overexposure.... |
|
|
 | 2555 | Microscope:Controller | LEJ | FluoArc BP | | Available |
Description/Details: Automatic signal balance for image recording: FluoArc permits you to control the intensity of the excitation light via the brightness of the light source and therefore to receive signals of the required intensity. In computer-controlled multichannel fluorescence, the light intensity changes automatically. Manually or digitally controlled: FluoArc always provides optimum signals for perfect results.... |
|
|
 | 2996 | Microscope:Electron | Jeol | JSM-T300 | | Available |
Description/Details:
# 6 mm resolution
# 15 by (WD = 48 mm) ~ 200,000 provided with automatic magnification correction device
# Accelerated voltage 1, 2, 5, 10, 15, 20, 25, 35
# Manual specimen stage X = 0-40 mm Y = 0-80 mm
# Secondary and back scattered detectors
# Fully automatic vacuum chambers... |
|
|
 | 2611 | Microscope:Inverted | Carl Zeiss | Axiovert 100 | | Available |
Description/Details: The Zeiss Axiovert 100 is a high-end inverted research-grade microscope for brightfield and fluorescence applications. The microscope is especially well suited for live cell imaging and low-light fluorescence microscopy. ... |
|
|
 | 2886 | Microscope:Inverted | Leica | DM IRB | | Available |
Description/Details: The Leica DM IRB inverted research microscope is the answer to all your inverted research microscopy requirements. The Leica DM IRB is the logical development of Leica's tried and tested inverted research microscopes. This system was developed in cooperation with users
and laboratories all over the world, and with the experience of 150 years of optics in Wetzlar, Germany.Key Features
Compact, stable and ergonomic design
Effective contrasting methods for unlimited life science applications such as Brightfield, Phase Contrast, Darkfield Contrast, Polarization Contrast, Leica Modulation Contrast, DIC and Fluorescence Unique feature: Optimized Fluorescence with a 4 position filter cube turret (manual or motorized) without pixel shift, including BG 38 and light stop
Unique feature: Light fiber encoupling to protect the instrument against heat of the lamp
Unique feature: Centerable and adjustable field and aperture diaphragm for fluorescence
Unique feature: Tilting (15°-45°) ... |
|
|
 | 2929 | Microscope:Inverted | Nikon | Diaphot 200 | | Available |
Description/Details:
This workhorse tissue culture microscope features advanced optical design for the shortest, most efficient light path. Incorporated as a part of the built-in turret assembly is a focusable Bertrand lens, photomask reticle and dark slide.
The Diaphot microscope was designed for photomicrography, with photographic capability built into the optical system. The optical design utilizes a built-in binocular body, inclined at 45 degrees, and only one reflecting surface in the microscope body to reduce reflections and glare and maximize image contrast.
The Diaphot is equipped with a Siedentopf-design binocular head built onto a die-cast body. A focusing Bertrand Lens is built into the binocular body for fast alignment of the phase annular ring. A dark slide position is incorporated in the turret to cut off stray light from the optical system during time lapse cinemicrography as well as a low-power focusing magnifier for critically sharp photomicrography with the 2x and 4x objectives.
The s... |
|
|
 | 4599 | Microscope:Inverted | Carl Zeiss | Axiovert 25 | | Available |
Description/Details: The small inverted microscope from Carl Zeiss: brilliant optics, high-quality components and, last but certainly not least, outstanding stability. The ideal solution not only for your routine work. Compact and ergonomic, with a stage height of only 190 mm.... |
|
|
 | 4898 | Microscope:Inverted | Wilovert | Wetzlar 21 | 06330 | Available |
Description/Details: Includes The Following;
- CFWE 10XA/18 Eyepieces
- Phase Attachment w/Ph1 & Ph2 Phase Rings
- Nikon E 10 - 0.25 - 160/- - Ph1 DL (10x Objective)
- Nikon 20 - 0.4 - 160/1.2 - Ph2 DL (20x Objective)
- Standard Stage
- Illuminator
- Blue Filter
- Operator’s Manuals... |
|
|
 | 4899 | Microscope:Inverted | Carl Zeiss | 471203-9901 | | Available |
Description/Details: The small inverted microscope from Carl Zeiss: brilliant optics, high-quality components and, last but certainly not least, outstanding stability. The ideal solution not only for your routine work. Axiovert 25, one microscope - three models.
Compact and ergonomic, with a stage height of only 190 mm.... |
|
|
 | 5525 | Microscope:Inverted | Nikon | TMS-F | | Available |
Description/Details: Nikon TMS Inverted Objective Flatfield Scope: CWF 15x eyepieces; mechanical stage w/coaxial X,Y movement controls; Diascopic light source; 4 position objective turret... |
|
|
 | 6352 | Microscope:Inverted | Carl Zeiss | Axiovert 10 | 45 17 00 | Available |
Description/Details: with Sony AVC/D7 CCD video camera |
|
|
 | 4653 | Microscope:Light Source | Schott Fostec LLC | DCR II | | Available |
Description/Details: DCR II is a 150-watt regulated light source. Low voltage ripple is rated at only 1 percent peak to peak. The regulated power supply eliminates flicker dips and surges, providing a stable light output.
The power supply regulates line voltage fluctuations of up to ± 15 percent and the light generated will not vary more than ± .5 percent. A built-in 9-pin connector can be accessed with an analog input (0 to 5 VDC) to control light intensity.
Rated Power Output 200 Watts Output Voltage 0.0, 0.5 to 20.5 VDC Input Voltage Rating, 50/60 Hz. 90 to 265 VAC Power Factor Correction @ 230 VAC, 50 Hz. > 0.99, < 4° Hold-up Time, Nominal AC Input, Full Load 8.3 milliseconds Line Regulation, Over Entire Input Range ±0.05% Current Limit Set Point 8.5 Amps Temperature Range: Operating 0° to 45°C Storage -25° to 85°C Relative Humidity, Non-condensing 5% to 95% Vibration Tests: 3 Orthagonal Axes, 0.75g peak, 5 to 500Hz at 1 oct/min. 2 hrs. each axis, 1.5g for 5 m... |
|