 | 3034 | Imager:Camera | Alpha Innotech | 8710-8/001 | | Available |
Description/Details: Camera & Stand Sold Together |
|
|
 | 5465 | Imager:Camera | Tektronix | C-7 | | Available |
Description/Details: The C-7 was designed so that the user will not have to handle prints until they are completely developed. This is especially important in medical or clean-room applications where film handling may cause chemical contamination. The C-7 and film types 331 and 339 are certified for use inside class 100 clean rooms. Another benefit is that the rollers will not have to be cleaned as often since the chemicals are contained inside the print... |
|
|
 | 4798 | Imager:Camera Controller | IonOptix | Video Power | | Available |
Description/Details: |
|
|
 | 5706 | Imager:Cassette | Spectroline | Monotec | | Available |
Description/Details: 8 X 10
In autoradiography, a radioactively labeled probe is hybridized with a specimen material which is contained in a gel (polyacrylamide or agarose) or on a membrane (nylon or nitrocellulose). The hybridized specimen is then placed inside a cassette where it is in contact with a high-speed X-ray film. After the cassette is stored at a temperature of -70°C for a few days, the radioactivity forms an image representing the spatial distribution of the sample under investigation.... |
|
|
 | 3041 | Imager:Eraser | Fuji | Image Eraser 3 | IPE4046 | Available |
Description/Details: Image Eraser is a specially designed light box used to erase latent images formed on storage phosphor screens.... |
|
|
 | 5416 | Imager:Eraser | Amersham Biosciences | Image Eraser | 810-UNV | Available |
Description/Details: Image Eraser - Erases storage phosphor screens for reuse. The Storm instrument connects to a computer (not included) running the Microsoft Windows operating system and uses Scanner Control software (ImageQuant TL). This Storm instrument scans samples using the Storage phosphor scan acquisition mode.... |
|
|
 | 2807 | Imager:Fluorescence | Molecular Dynamics | FluorImager 595 | F1595 | Available |
Description/Details: Molecular Dynamics' FluorImager(TM) 595 system enables researchers to perform multiple-color fluorescent DNA analysis on PCR (polymerase chain reaction) gel samples prepared using conventional sample preparation equipment.
The system's two-color capability allows researchers to run mixtures of PCR products and internal standards together in the same electrophoresis gel lanes to achieve higher levels of throughput and accuracy.
... |
|
|
 | 5168 | Imager:Fluorescence | Perkin Elmer | ImageTrak | | Available |
Description/Details: The ImageTrak is an innovative system that integrates fiber optic epi-fluorescence imaging with PlateTrak automated liquid handling robotics to provide a high capacity, high throughput system for assay miniaturization and lead optimization. The ImageTrak is unique in its ability to combine proven Packard automation, sensitive imaging techniques and data analysis features into one complete system for high throughput screening. Two ImageTrak models are available to handle varied assay requirements. Each system is equipped with 96-channel dispensing for automated processing of 96 to 1536-well high-density microplates, a bi-directional conveyor for secure plate handling and an epi-fluorescence imaging module in a light tight enclosure. Based on patented “contact imaging” technology, the ImageTrak uses fiber optics and a cooled CCD camera to achieve a high level of sensitivity, enabling this integrated system to handle many different assays. The ImageTrak utilizes 96 individual ... |
|
|
 | 6519 | Imager:Fluorescence | Li-Cor Biosciences | Odyssey 9120 | | Available |
Description/Details: Features the Following:
- Wide Linear Range
- Two Color - Lane normalization increases quantification accuracy
- High Sensitivity – Equal to or better than Chemiluminescence
- Direct Detection – No film, darkroom, or messy substrates
- Clear Data – No loss of weak bands due to overexposed bands
- Superior Versatility – Image a variety of applications with infrared fluorescence
Specifications:
- 700 Channel Laser Source: Solid-state diode laser at 680 nm
- 800 Channel Laser Source: Solid-state diode laser at 780 nm
- Detectors: Silicon avalanche photodiodes
- Scanning Speed: 5-40 cm/s
- Resolution: 21-337 μm
- Power Requirements: Auto voltage selection @ 90-250 VAC & 47-63 Hz; 1.1A @ 120V; 200W max
- Dimensions: 37 h x 53 w x 58... |
|
|
 | 5043 | Imager:Fluorescence Fan Module | Molecular Dynamics | F1595-P/S | | Available |
Description/Details: |
|
|
 | 5471 | Imager:liquid cooling | Alpha Innotech | LCU1 | | Available |
Description/Details: Liquid Cooling Unit for Imaging System |
|
|
 | 3379 | Imager:Multi-Detection | Bio-Rad Laboratories | Gel VersaDoc | 3000 | Available |
Description/Details: The Bio-Rad model 3000 VersaDoc Gel Imaging System is designed to capture and analyze digital images from a wide range of samples, including gels, blots, autoradiograms, TCL plates and microplates.... |
|
|
 | 3573 | Imager:Multi-Detection | Molecular Dynamics | Storm 840 | | Available |
Description/Details: The Storm 840 Gel and Blot Imaging System offers filmless autoradiography, fluorescence and chemifluorescence imaging.... |
|
|
 | 3926 | Imager:Multi-Detection | Molecular Dynamics | Storm 860 | | Available |
Description/Details: Provides the capacity to rapidly and quantitatively analyze radioactivity(32P, 35S, 14C, and 125l) patterns on two dimensional substrates such as Southern, Northern, dot and slot blots, CAT assays, and dried gels. A densitometer allows imaging of non-radioactive substrates. User-friendly instrumentation allows hands-on analysis of a sample directly by the investigator. A Fluorimager allows quantitation of chemifluorescence and red and blue fluorescent samples.... |
|
|
 | 2987 | Imager:Multi-Detection | Molecular Dynamics | Densitometer SI | 375 | Available |
Description/Details: Personal Densitometer SI uses a laser scanner to quantify stained electrophoresis gels, autoradiographic films, and blotting membranes.
Highly sensitive laser-based transmission densitometer.
Linear range from 0.1-3.5 OD.
High-efficiency light collection for accurate quantification.
Personal Densitometer SI uses a laser scanner and light-integrating cylinder to quantify stained electrophoresis gels, blotting membranes, and films exposed by chemiluminescence or radiochemicals. The entire sample area is rapidly imaged as a laser beam scans in one direction while the sample moves in the perpendicular direction. High spatial resolution captures the complete detail of any gel, blot, or film. Personal Densitometer SI enables quantitative image analysis for a comprehensive variety of sample types and provides outstanding linearity, sensitivity, and resolution.
... |
|
|
 | 5146 | Imager:Multi-Detection | Bio-Rad Laboratories | Fluor-S | | Available |
Description/Details: The Fluor-S MultiImager is a quantitative imaging system for capturing high resolution digital images from single and multi-color fluorescence, chemiluminescence, chemifluorescence, and colorimetric samples. Using cooled CCD technology in combination with a unique ultraviolet illumination mechanism and a highly efficient optical design, the Fluor-S offers researchers the sensitivity, uniformity, flexibility, and dynamic range they require for the analysis of electrophoretic samples. With direct imaging and automated acqusition, this system can increase laboratory throughput and eliminate the need for detection methods using x-ray film.... |
|
|
 | 5415 | Imager:Multi-Detection | Molecular Dynamics | Storm 840 | | Available |
Description/Details: The Storm 840 is designed as a less expensive model that includes the PhosphorImager technology and chemifluorescence. The Storm 840 is field upgradeable to a Storm 860 by adding the capability for red-excited fluorescence.
A photographic technique used to localize a radioactive substance within a solid specimen; also known as radioautography.
A photographic emulsion is placed in contact with the object to be tested and is left for several hours, days, or as a core imaging technique. By offering autoradiography capability plus the two new non-radioactive techniques for gels and blots, the Storm system provides a powerful transition path for labs that are under pressure to reduce radioisotope radioisotope
... |
|
|
 | 5864 | Imager:Multi-Detection | Bio-Rad Laboratories | Fluor-S Max | Multiimager | Available |
Description/Details: The Fluor-S MAX MultiImager is a quantitative imaging system for capturing digital data from single and multi-color fluorescence, chemiluminescence, chemifluorescence and colorinetric samples. Using super-cooled CCD technology in combination with a unique ultraviolet illumination mechanism and high efficiency, the Fluor- S MAX offers high sensitivity, uniformity, flexibility and dynamic range for the analysis of electrophoretic samples. The Personal Molecular Imager FX system is the most flexible isotope imaging system available, offering radioisotopic imaging using your choice of phospher screen. The Personal Molecular Imager accomodates both large (35 x 43 cm) and small (20 x 25 cm) storage phospher screens. ... |
|
|
 | 3040 | Imager:Phosphor | Fuji | Phosphor | IPR1800 | Available |
Description/Details: Especially suited for highthroughput macro array image analysis the Fujifilm BAS-1800II provides the ideal configuration for a low-cost imager that
requires only a small amount of space in the laboratory. Despite its small size, this unit delivers powerful performance including the high level of quantitative accuracy, resolution and linearity of data you have learned to expect from
Fujifilm Bio-imaging Analyzers (BAS). An optimized system for macro array image analysis, the BAS 1800II features an enlarged imaging area of 23 cm x 25 cm, for use with 22 cm x 22 cm membranes, and optional macro array analysis software for use with Windows® 95, Windows® 98, and Windows® NT ver.4.0.
This makes the BAS 1800II the most suitable
imager for macro array image analysis.... |
|
|
 | 2614 | Imager:Phosphor | Fujix | BAS-1000 | | Sold |
Description/Details: The BAS-1000 maintains a high level of quantitative accuracy, resolution and linearity of data that the pioneer of Bio-imaging Analyzer Systems has come to be known for, while requiring only little space in the laboratory. ... |
|